Products
Tel: 0086 -0592-2213035
Fax: 0086 -0592-5058034
Address: No.552, Tongji North Road, Tong'an District, Xiamen
Marine power cable
Current Location : HomePage > Products
Marine power cable

  Executive Standard
  This product is made according to the standard entitled GB9331 (IEC-365).

  Usage
  It is suitable for the power, lighting and general control devices of various ships and other over-water buildings like offshore oil platforms and its rated voltage is 0.6/KV.

  Model and Name

 

Model Name
CJV 92 / DA  XLPE Insulated, PVC sheathed steel wire braided armored PVC outer sheath marine power cable DA type , SA model , SB -type
CJS / SC XLPE insulation, the flame retardant polyolefin sheathed shipboard power cable SC -type
CJS80/SC XLPE insulation, the flame retardant jacket bare copper wire braid armored marine power cable SC -type
CJS90/SC XLPE insulation, the flame retardant polyolefin sheath bare wire braided armored marine power cable SC -type
CJ8S/SC XLPE insulation, the flame retardant jacket bare copper wire braid armored flame retardant sheathed shipboard power cable SC -type
CJ9S/SC XLPE insulation, the bare wire braided sheath flame retardant halogen-free flame-retardant polyolefin sheathed armored marine power cable SC -type

 

Description of Each Code in Model

Item Code Description
series CE EPR insulated shipboard control power cables
CJ XLPE insulated shipboard power cable
CV PVC insulated shipboard power cable
CS Silicone rubber insulated shipboard power cable
CX Natural a rubber insulated shipboard power cable
inner sleeve V PVC
F Neoprene
H CSM
( Omitted ) Without armor
armored 8 Copper braid
9 Steel braided
2 Double steel
3 Round wire

 

  Characteristic Features
  ① Rated voltage for U0 / U: 0.6/1KV.
  ② In addition to the flexible cables for mobile devices, others are all laid permanently. The minimum bending radius of the cable while laying is listed in following table.

Structural features of cable Outside diameter of cable B The minimum Internal bending radius
Metal braided armored Any value 6D
Non- armored type D ≤ 25 4D
D> 25 6D

  ③ The lowest temperature for laying cable

  It is -15℃ for the PVC sheath while -20℃ for others.
  Combustion characteristics
  ④Combustion Characteristics of the Cable
  Single-vertical flame-retardant (/ DA) cables can withstand the single-vertical burning test specified by GB12666.2 (IEC332-1).
Bunched flame-retardant (/ SA) cables can withstand the bunched burning test specified by GB12666.5 (IEC332-3).
  LSF bunched flame-retardant (/ SB) cables can withstand the bunched burning test prescribed by GB12666.5 (IEC332-3), and the concentration of smoke when burned is in line with the corresponding regulations of GB12666.7 (IEC1034) while the HCL content of the combustion gases precipitated should be no more than 100mg / g which is in line with the standard entitled IEC754-1.
  LSF bunched flame-retardant (/ SC) cables can withstand the bunched burning test prescribed by GB12666.5 (IEC332-3), and the concentration of smoke when burned is in line with the corresponding regulations of GB12666.7 (IEC1034). Besides, the PH value of the combustion gases precipitated is supposed to be no less than 4.3, while the conductivity ≤10μS/mm is in compliance with the required index of IEC754- 2.
  ⑤ Assumed Flow of Cable: four cables are to be laid in the ambient temperature at 45 ℃, and the conductor’s temperature should be controlled within the calculated values of the allowable working temperature continuously.